2. Albin RL, Young AB, Penney JB. The functional anatomy of basal ganglia disorders. Trends Neurosci 1989;12:366-75
3. Pollak P, Benabid AL, Gross C, Gao DM, Laurent A, Benazzouz A, et al. Effets de la stimulation du noyau sous-thalamique dans la maladie de Parkinson [Effects of the stimulation of the subthalamic nucleus in Parkinson disease]. Rev Neurol (Paris) 1993;149:175-6. French
5. Castrioto A, Lozano AM, Poon YY, Lang AE, Fallis M, Moro E. Ten-year outcome of subthalamic stimulation in Parkinson disease: a blinded evaluation. Arch Neurol 2011;68:1550-6
6. Krack P, Batir A, Van Blercom N, Chabardes S, Fraix V, Ardouin C, et al. Five-year follow-up of bilateral stimulation of the subthalamic nucleus in advanced Parkinson’s disease. N Engl J Med 2003;349:1925-34
7. Pereira EA, Green AL, Aziz TZ. Chapter 23 - Deep brain stimulation for pain. Handb Clin Neurol 2013;116:277-94
9. Mayberg HS, Lozano AM, Voon V, McNeely HE, Seminowicz D, Hamani C, et al. Deep brain stimulation for treatment-resistant depression. Neuron 2005;45:651-60
10. Sobstyl M, Stapińska-Syniec A, Sokół-Szawłowska M, Kupryjaniuk A. Deep brain stimulation for the treatment of severe intractable anorexia nervosa. Br J Neurosurg 2019;33:601-7
18. Finelli DA, Rezai AR, Ruggieri PM, Tkach JA, Nyenhuis JA, Hrdlicka G, et al. MR imaging-related heating of deep brain stimulation electrodes: in vitro study. AJNR Am J Neuroradiol 2002;23:1795-802
19. Rezai AR, Phillips M, Baker KB, Sharan AD, Nyenhuis J, Tkach J, et al. Neurostimulation system used for deep brain stimulation (DBS): MR safety issues and implications of failing to follow safety recommendations. Invest Radiol 2004;39:300-3
21. Medtronic. Lead Kit for Deep Brain Stimulation, 3387, 3389, Implant Manual. Minneapolis : Medtronic, 2002
22. Riordan AT, Gamache C, Fosko SW. Electrosurgery and cardiac devices. J Am Acad Dermatol 1997;37:250-5
23. Nutt JG, Anderson VC, Peacock JH, Hammerstad JP, Burchiel KJ. DBS and diathermy interaction induces severe CNS damage. Neurology 2001;56:1384-6
24. Ruggera PS, Witters DM, von Maltzahn G, Bassen HI. In vitro assessment of tissue heating near metallic medical implants by exposure to pulsed radio frequency diathermy. Phys Med Biol 2003;48:2919-28
25. Medtronic. Electrocautery/Surgery Standard Letter. Dublin : Medtronic, 2014
26. Senthuran S, Toff WD, Vuylsteke A, Solesbury PM, Menon DK. Editorial III: implanted cardiac pacemakers and defibrillators in anaesthetic practice. Br J Anaesth 2002;88:627-31
28. Domino KB, Smith TC. Electrocautery-induced reprogramming of a pacemaker using a precordial magnet. Anesth Analg 1983;62:609-12
29. American Society of Anesthesiologists. Practice advisory for the perioperative management of patients with cardiac implantable electronic devices: pacemakers and implantable cardioverter-defibrillators: an updated report by the american society of anesthesiologists task force on perioperative management of patients with cardiac implantable electronic devices. Anesthesiology 2011;114:247-61
31. Martin WA, Camenzind E, Burkhard PR. ECG artifact due to deep brain stimulation. Lancet 2003;361:1431
32. Singh M, Venkatraghavan L. Cortical arousal with deep brain stimulation after general anesthesia for laparoscopic cholecystectomy. J Neurosurg Anesthesiol 2018;30:77-8
33. National Center for Biotechnology Information. PubChem Compound Summary for CID 6047, Levodopa [Internet]. Bethesda: National Center for Biotechnology Information; cited 2022 Apr 29. Available from:
https://pubchem.ncbi.nlm.nih.gov/compound/Levodopa
35. Ozturk F, Osher RH. Phacoemulsification in a patient with a deep brain stimulator. J Cataract Refract Surg 2006;32:687-8
38. Hashii H, Hashimoto T, Okawa A, Shida K, Isobe T, Hanmura M, et al. Comparison of the effects of high-energy photon beam irradiation (10 and 18 MV) on 2 types of implantable cardioverter-defibrillators. Int J Radiat Oncol Biol Phys 2013;85:840-5
39. Elders J, Kunze-Busch M, Smeenk RJ, Smeets JL. High incidence of implantable cardioverter defibrillator malfunctions during radiation therapy: neutrons as a probable cause of soft errors. Europace 2013;15:60-5
44. Rosenow JM, Tarkin H, Zias E, Sorbera C, Mogilner A. Simultaneous use of bilateral subthalamic nucleus stimulators and an implantable cardiac defibrillator. Case report. J Neurosurg 2003;99:167-9
45. Moscarillo FM, Annunziata CM. ECT in a patient with a deep brain-stimulating electrode in place. J ECT 2000;16:287-90
46. Chou KL, Hurtig HI, Jaggi JL, Baltuch GH, Pelchat RJ, Weintraub D. Electroconvulsive therapy for depression in a Parkinson’s disease patient with bilateral subthalamic nucleus deep brain stimulators. Parkinsonism Relat Disord 2005;11:403-6
47. Capelle HH, Simpson RK Jr, Kronenbuerger M, Michaelsen J, Tronnier V, Krauss JK. Long-term deep brain stimulation in elderly patients with cardiac pacemakers. J Neurosurg 2005;102:53-9
48. Ozben B, Bilge AK, Yilmaz E, Adalet K. Implantation of a permanent pacemaker in a patient with severe Parkinson’s disease and a preexisting bilateral deep brain stimulator. Int Heart J 2006;47:803-10
49. Obwegeser AA, Uitti RJ, Turk MF, Wszolek UM, Flipse TR, Smallridge RC, et al. Simultaneous thalamic deep brain stimulation and implantable cardioverter-defibrillator. Mayo Clin Proc 2001;76:87-9
50. Doyle SR, Kremer MJ. AANA journal course. Update for nurse anesthetists. Parkinson disease. AANA J 2003;71:229-34